<LOGO>
FM Transmitter Measurement Report
Created: 2026-08-20 11-43-53
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.50 MHz 5/5, 67 dBuV BOOST FI
Pilot RDS Phase Difference
6.5 kHz 3.4 kHz 25 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 67 kHz 11204 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,5 dBr 5,36 dBr 6,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"BOOST FI" 4E31 10 (Pop M) 1 0 1 1 11:43, 20.08.2026
RT
"BOOST RADIO Finnland (Reg Test DSN3) "
AF EON
92.8, 96.6, 103.9, 105.5 MHz -
FM Scope Max at: 67 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2026.08.20 11.42.49 Total samples: 11204 Equivalent time: 0:09:20 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,9 dBr MIN: 2,5 dBr AVE: 5,36 dBr % above 12,2 dBr: 0,0 Last value: 4,3 dBr (2026.08.20 11.42.49) 11.28 11.30 11.32 11.34 11.36 11.38 11.40 11.42 0 2 4 6 Pm [dBr]